器件名称: HY12-P/SP1
功能描述: Current Transducers HY 5 to 25-P/SP1
文件大小: 141.28KB 共2页
简 介:Current Transducers HY 5 to 25-P/SP1
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit) with unipolar power supply.
IPN
=
5 .. 25 A
Electrical data
Primary nominal r.m.s. current IPN (A) 5 10 12.5 15 20 25 Primary current measuring range IP(A) ± 15 ± 30 ± 37.5 ± 45 ± 60 ± 75 Primary conductor (mm) Type
Features
HY HY HY HY HY HY 05-P/SP1 10-P/SP1 12-P/SP1 15-P/SP1 20-P/SP1 25-P/SP1
0.7 1.1 1.4 1.4 2 x 1.2 1) 2 x 1.4 1)
Hall effect measuring principle Galvanic isolation between primary Isolation voltage 2500 V~ Compact design for PCB mounting Low power consumption Extended measuring range (3 x IPN) Insulated plastic case recognized
according to UL 94-V0. and secondary circuit
VC IC P Vd Vb R IS VOUT ROUT RL
Supply voltage (± 5 %) single Current consumption Overload capability (1 ms) R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn R.m.s. rated voltage, safe separation Isolation resistance @ 500 VDC Output voltage @ + IPN, RL = 10 k, TA = 25°C Output voltage @ - IPN, RL = 10 k, TA = 25°C Output internal resistance Load resistance
+5 10 50 x IPN 2.5 5002) > 1000 2.5 1.5 100 >1
V DC mA kV V M V V k
Advantages
Easy mounting Small size and space saving Only one design for wide current High immunity against external
interference. ratings range
Accuracy - Dynamic performance data
ε
X
L
VOE VOH VOT TCε G tr di/dt f
Accura……