器件名称: U210B1
功能描述: Phase Control Circuit Load Current Feedback Applications
文件大小: 166.64KB 共12页
简 介:U210B1
Phase Control Circuit–Load Current Feedback Applications
Description
The interated circuit, U210B1, is designed as a phasecontrol circuit for load-current feedback application in bipolar technology. To realize motor control systems, it has integrated load current detection, voltage monitoring and soft-start functions. The voltage obtained due to load current proportionality, can be used according to the application i.e., load-current compensation or loadcurrent regulation.
Features
D D D D D
Externally controlled integrated amplifier Variable soft start Automatic retriggering Voltage and current synchronization Triggering pulse typ. 125 mA Package: DIP14
D Internal supply voltage monitoring D Temperature constant reference source D Current requirement ≤ 3 mA
14 Voltage detector
1 Current detector Automatic retriggering Output pulse 4
5 Control amplifier 6
8
+ –
7
Phase control unit = f (V12)
3 Supply voltage limitation Reference voltage Voltage monitoring 2 13
–VS GND
Load current detection
Soft start
12
11
9
10
95 10686
Figure 1. Block diagram
TELEFUNKEN Semiconductors Rev. A1, 28-May-96
1 (12)
U210B1
2 (12)
1N4007 D1 R1 M L 18 k W 1.5 W R3 220 kW
95 10693
R4 470 k W 1 Current detector Output pulse 5 6 3 Supply voltage limitation Reference voltage Voltage monitoring R 2 220 k W 10 nF C2 2 –VS 13 GND C1 C5 100 W Automatic retriggering 4 R 12 BTA 12–800
14 Voltage detector
R9 10 kW
Set speed voltage
VM = 230 V
X