器件名称: CS294GN8
功能描述: Ground Fault Interrupter
文件大小: 120.22KB 共4页
简 介:CS294
CS294 Ground Fault Interrupter
Description
The CS294 is an AC outlet ground fault interrupter controller IC. The IC detects the presence of hazardous grounding conditions and open circuits the AC line before a dangerous shock can occur. The CS294 contains an operational amplifier, an SCR driver and a 24V zener shunt regulator. Two sense coils, a bridge rectifier, a relay and an SCR are required as external components. The completed interrupter circuit can detect and protect against both hot wire to ground faults and neutral wire to ground faults. The CS294 is built on a 30V bipolar process and is available in 8 lead DIP packages.
Features
s Supply Derived from AC Supply 24V s Direct Interface to SCR s Adjustable Sensitivity s Grounded Neutral Fault Detection
Block Diagram
AmpOUT +VS
VFB 20kW Signal Common 10kW Filter Bias +
50kW
+ SCR Trigger + 4.7kW
Package Options
8 Lead PDIP & SO Narrow
VFB 1 Filter Signal Common Gnd
Detect AmpOUT +VS SCR Trigger
Gnd
Detect
Cherry Semiconductor Corporation 2000 South County Trail, East Greenwich, RI 02818 Tel: (401)885-3600 Fax: (401)885-5786 Email: info@cherry-semi.com Web Site: www.cherry-semi.com
Rev. 1/20/99
1
A
¨
Company
CS294
Absolute Maximum Ratings Operating Junction Temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150C Lead Temperature Soldering: Wave Solder (through hole styles only) . . . . . . . . . . . . .……